              進入中文版  繁體中文 前, 要設定延遲翻譯時間, 如100表示100ms,默認為0 var cookieDomain = "/"; //Cookie地址, 一定要設定, 通常為你的網址 var msgToTraditionalChinese = "繁體中文"; //默認切換為繁體時顯示的中文字符 var msgToSimplifiedChinese = "簡體中文"; //默認切換為簡體時顯示的中文字符 var translateButtonId = "translateLink"; //默認互換id translateInitilization(); 進入英文版  ENGLISH
              聯系我們

              電話: +86-550-7309278
              傳真: +86-550-7309288
              手機: +86-13905505237
              E-mail: 13905505237@163.com
              地址: 安徽省天長市經濟開發區天汊路128號
              QQ: 641289349
              QQ: 641289349

              產品展示 > 架空絕緣電纜 > > Single Conductor 600 V Secondary Type UD Cable Aluminum Conductor
              產品名稱 : Single Conductor 600 V Secondary Type UD Cable Aluminum Conductor
               放大產品                返回上一頁
              ←[上一個產品]              [下一個產品]→


              詳細說明:
              Applications
              Directly buried or installed in ducts for 600 volt secondary distribution.

              Construction
              Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation.

              Standards
              Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifications.
              B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
              B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
              B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
              B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
              Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
              "USE-2" per UL 854 available upon request.

              Options
              Cable in Duct (CIC)
              Abrasion Resistant

              Ampacity
              90oC conductor temperature, 20oC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
               
              Item Code:
               Princeton
               Mercer
               Clemson
               Kenyon
               Harvard
               Yale
               Tufts
               Beloit
               Hofstra
               Gonzaga
               Rutgers
               Emory
               Duke
               Furman
               Sewanee
               Fordham

              相關產品:
              三芯ABC電纜
              三芯ABC電纜
              四芯ABC電纜
              四芯ABC電纜
              600 Volt Underground XLPE 90°C Service and Secondary Cable
              600 Volt Underground XLPE 90°C Service and Secondary Cable
              AL USE-2/RHH/RHW-2
              AL USE-2/RHH/RHW-2
              二芯ABC電纜
              二芯ABC電纜